Hot Products

Quick Index

A B C D E F G H I J K L M N O P Q R S T U V W S Y Z

Contact

How to choose filter media type?

2011-12-01 14:16:35

how can you choose the right filter media for you filter bag?Choosing the correct filter media for your dust collector bag filter is an extremely important and sometimes difficult process. U.S. Bag filter media is chosen based upon the type of application that they will be used for. When selecting a media, the following things must be taken into consideration. Keep in mind that bag filter performance is directly related to how well it can tolerate the environment in which it is being used, how efficiently it is able to remove dust particles from it's fabric, and it's ability to be cleaned by the dust collector. As a starting point, it is helpful to identify the type of filter media currently used in the application.

Dust Collector Filter Fabrics technical data

Bag Filters - Fabric Selection
Polyprop. Polyester Acrylic Fiber-glass Nomex Ryton P 84 Teflon Ceramic
Temperature 170 F 275 F 285 F 500 F 375 F 375 F 500 F 500 F 1600 F
Abrasion Great Great Good Fair Great Good Fair Good Fair
Energy Absorption Good Great Good Fair Good Good Good Good Fair
Filtration Properties Good Great Good Fair Great Great Great Fair Fair
Moist Heat Great Poor Great Great Good Good Good Great Great
Alkalines Great Fair Fair Fair Good Great Fair Great Fair
Mineral Acids Great Fair Good Good Fair Great Good Great Poor
Oxygen (10%+) Great Great Great Great Great Poor Great Great Great
Polyester Felt
Recommended continuous operation temperature: 275F
Maximum (short time) operation temperature: 300F
Supports combustion: Yes
Biological resistance (bacteria, mildew): No Effect
Resistance to alkalis:Fair
Resistance to mineral acids: Fair+
Resistance to organic acids: Fair
Resistance to oxidizing agents: Good
Resistance to organic solvents: Good
Available weights: 10 oz. - 22 oz.
Polypropylene Felt
Recommended continuous operation temperature: 190F
Maximum (short time) operation temperature: 210F
Supports combustion: Yes
Biological resistance (bacteria, mildew): Excellent
Resistance to alkalis: Excellent
Resistance to mineral acids: Excellent
Resistance to organic acids: Excellent
Resistance to oxidizing agents: Good Resistance to organic solvents:
Excellent
Available weights: 12 oz. - 18 oz
Combo Felt
Recommended continuous operation temperature: 210F
Maximum (short time) operation temperature: 225F
Supports combustion: Yes
Biological resistance (bacteria, mildew): Good
Resistance to alkalis: Good
Resistance to mineral acids: Good
Resistance to organic acids: Good
Resistance to oxidizing agents: Good
Resistance to organic solvents: Good
Available weights: 12 oz. - 18 oz.
Dust Collector Filter High Temperature Materials
Conex / Nomex Felt (Aramid)
Recommended continuous operation temperature: 400F
Maximum (short time) operation temperature: 425F
Supports combustion: No
Biological resistance (bacteria, mildew): No Effect
Resistance to alkalis: Good
Resistance to mineral acids: Fair
Resistance to organic acids: Fair+
Resistance to oxidizing agents: Poor
Resistance to organic solvents: Good
Available weights: 10 oz. - 22 oz.
P84 Felt Polyimide
Recommended continuous operation temperature: 475F
Maximum (short time) operation temperature: 500F
Supports combustion: No
Biological resistance (bacteria, mildew): No Effect
Resistance to alkalis: Fair
Resistance to mineral acids: Good+
Resistance to organic acids: Good+
Resistance to oxidizing agents: Good+
Resistance to organic solvents: Excellent
Available weights: 14 oz. - 18 oz.
Ryton Felt / PPS
Recommended continuous operation temperature: 375F
Maximum (short time) operation temperature: 400F
Supports combustion: No
Biological resistance (bacteria, mildew): No Effect
Resistance to alkalis: Excellent
Resistance to mineral acids: Excellent
Resistance to organic acids: Excellent
Resistance to oxidizing agents: Fair
Resistance to organic solvents: Excellent
Available weights: 16 oz. - 18 oz.
Dust Collector Filter Specialty Materials
Homopolymer Acrylic Felt
Recommended continuous operation temperature: 250F
Maximum (short time) operation temperature: 275F
Supports combustion: Yes
Biological resistance (bacteria, mildew): Good+
Resistance to alkalis: Fair
Resistance to mineral acids: Good+
Resistance to organic acids: Excellent
Resistance to oxidizing agents: Good
Resistance to organic solvents: Good+
Available weights: 15 oz. - 18 oz.
Epitropic Felt Antistatic
Recommended continuous operation temperature: 275F
Maximum (short time) operation temperature: 300F
Supports combustion: Yes
Biological resistance (bacteria, mildew): No Effect
Resistance to alkalis: Fair
Resistance to mineral acids: Fair+
Resistance to organic acids: Fair
Resistance to oxidizing agents: Good
Resistance to organic solvents: Good
Available weights: 14 oz. - 16 oz.